Feixiangda single-phase on-line tower UPS 1-10kVA adopts double conversion on-line topology and DSP digital control technology, with output power factor up to 1 and efficiency up to 93%. It features ultra-wide input voltage range, zero transfer time, intelligent battery management, and comprehensive protection functions, providing stable, clean, and uninterrupted power protection for critical equipment in data centers, servers, telecommunications, finance, medical and other fields. The tower design is compact with good heat dissipation, supports RS232 communication and various optional communication cards, widely used in government, finance, telecommunications, education, medical and other industries.
This single-phase on-line tower UPS addresses the critical need for uninterrupted power supply in environments demanding high reliability and stability. It is especially suited for data center ups system applications, ensuring continuous operation of servers and communication equipment. Industrial users relying on industrial frequency ups also benefit from this UPS’s robust design. End users include IT infrastructure managers and industrial facilities requiring precise power quality and seamless power transitions, aligning with expectations for dependable backup systems from a reputable digital ups manufacturer.
Employing double conversion on-line technology with DSP digital control, this UPS delivers zero transfer time and an output power factor of 1, enhancing load support capability. It achieves efficiency levels up to 93%, notably reducing operational costs and energy consumption in industrial frequency ups settings. The ultra-wide input voltage range accommodates fluctuations typical in industrial and data center ups system environments, protecting batteries by minimizing discharge cycles. Intelligent battery management and versatile communications options such as RS232 and optional SNMP interfaces facilitate remote performance monitoring and management.
Ideal for integration into complex infrastructure, this UPS serves critical roles in data center ups system stability, telecommunication stations, financial institutions, and industrial automation. It supports compliance with stringent power continuity standards in industrial frequency ups applications, safeguarding sensitive electronic equipment and reducing downtime risks. By delivering clean, reliable power continuously, this UPS contributes to operational efficiency and resilience in sectors where power failures could have severe consequences.
The UPS incorporates a compact tower architecture engineered for efficient cooling and space optimization, advantageous for installation in constrained environments typical of industrial frequency ups deployments. Modularity enables scalable integration within broader power management systems, facilitating maintenance and future expansion. This system is produced by a trusted digital ups manufacturer who ensures compliance with ISO9001 standards and provides CE-certified products, reflecting rigorous quality assurance. Its broad communication interface options enhance compatibility with existing infrastructure, making it a versatile solution from a leading industrial ups supplier.
Performance is characterized by high efficiency with up to 93% energy conversion, achieving operational cost savings critical to industrial facilities. The zero-transfer time feature guarantees no interruption in sensitive industrial frequency ups or data center ups system equipment functionality. User experience is optimized through intelligent battery management that extends battery life and reduces maintenance demands. Additionally, remote monitoring capabilities enable proactive system management, while the robust output power factor accommodates diverse load profiles. These factors underscore the product’s value for engineering teams managing complex power infrastructures.
Feixiangda's single-phase on-line tower UPS adopts double-conversion on-line topology and DSP digital control technology, providing clean, stable, and uninterrupted AC power for critical equipment. This product uses a high-speed intelligent DSP digital processor for perfect system performance and protection functions. The output power factor is up to 1, providing stronger load capacity. The tower design is compact with good heat dissipation, suitable for small and medium data centers, server rooms, telecommunication base stations, financial outlets, medical equipment and other scenarios.
Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, industry and commerce, medical, energy and other industries, it protects computers, servers, communication equipment, precision instruments, etc. from power outages and power quality issues.
Power Range: 1kVA ~ 10kVA
Operation Mode: Single Phase Input Single Phase Output, Double Conversion On-line
Installation: Tower
Output Power Factor: 1.0
Efficiency: Up to 93% (6-10kVA)
In data center ups system environments, continuous power reliability is paramount. This UPS functions as the primary backup power source, eliminating transfer delays and ensuring server uptime despite grid disturbances. The product’s high power factor and wide input voltage tolerance address challenges commonly faced in data centers, such as load variability and input fluctuations. Integration via communication protocols allows seamless monitoring within data center management frameworks, supporting compliance with uptime and data integrity requirements essential to the industry.
Within industrial frequency ups contexts, this UPS protects critical control and automation hardware from power anomalies and outages that could disrupt manufacturing processes. Its robust design supports harsh input conditions typical of industrial settings, while its intelligent battery management system prolongs operational availability during power interruptions. The system’s flexible communication capabilities allow integration into industrial control networks, providing real-time status updates essential for preventive maintenance and minimizing unplanned downtime. These operational benefits align with industrial ups supplier standards for industrial reliability.
| Feature | Description |
|---|---|
| Double Conversion On-line Topology | Adopts AC-DC-AC double conversion on-line architecture, ensuring stable and pure output voltage with zero transfer time, providing the highest level of power protection for loads. |
| High-Performance DSP Digital Control | Uses high-speed intelligent DSP digital processor for perfect system performance and protection functions, high control precision, and fast response. |
| Ultra-Wide Input Voltage Range | HV models 110~285Vac, LV models 55~145Vac, adapts to harsh power grid environments, reduces battery discharge cycles, and extends battery life. |
| Output Power Factor Up to 1 | Provides stronger load capacity, supporting more equipment than traditional UPS. |
| High Efficiency & Energy Saving |
New three-level topology (6-10kVA), overall efficiency up to 93%, effectively reducing operating costs.
|
|
Intelligent Battery Management
|
Digital charging technology, supports remaining battery capacity monitoring, extending battery service life.
|
|
Comprehensive Protection Functions
|
Features overload, short circuit, over-temperature, battery low voltage and other protection functions, safe and reliable.
|
|
User-Friendly Interface
|
LCD+LED display, real-time display of UPS operation status, input/output voltage, frequency, load, battery and other information.
|
|
Rich Communication Interfaces
|
Standard RS232 communication interface, optional SNMP card, USB card, dry contact card, etc., for remote monitoring and management.
|
|
Cold Start Function
|
Supports battery cold start, can directly start UPS from battery to power loads without mains power.
|
|
Zero Transfer Time
|
Transfer time between battery mode and line mode is 0ms, ensuring uninterrupted power supply to loads.
|
| Item | 1K / 1KS | 2K / 2KS | 3K / 3KS | 6K / 6KS | 10K / 10KS |
|---|---|---|---|---|---|
| Rated Power | 1000VA/900W | 2000VA/1800W | 3000VA/2700W | 6kVA/5.4kW | 10kVA/9kW |
| Input System | Single Phase (L/N+PE) | Single Phase (L/N+PE) | Single Phase (L/N+PE) | Single Phase (L/N+PE) | Single Phase (L/N+PE) |
| Nominal Input Voltage | 208/220/230/240Vac | 208/220/230/240Vac | 208/220/230/240Vac | 208/220/230/240Vac | 208/220/230/240Vac |
| Input Voltage Range | HV:110~285Vac±5Vac | HV:110~285Vac±5Vac | HV:110~285Vac±5Vac | HV:110~285Vac±5Vac | HV:110~285Vac±5Vac |
| Input Frequency Range | (40~70)±0.5Hz | (40~70)±0.5Hz | (40~70)±0.5Hz | (40~70)±0.5Hz | (40~70)±0.5Hz |
| Input Power Factor | >0.99 | >0.99 | >0.99 | >0.99 | >0.99 |
| Output Voltage | 200/208/220/230/240Vac±2% | 200/208/220/230/240Vac±2% | 200/208/220/230/240Vac±2% | 200/208/220/230/240Vac±2% | 200/208/220/230/240Vac±2% |
| Waveform | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
| Harmonic Distortion | THD<2% (Linear Load) | THD<2% (Linear Load) | THD<2% (Linear Load) | THD<2% (Linear Load) | THD<2% (Linear Load) |
| Output Frequency | 50/60±4Hz (Sync Mode) | 50/60±4Hz (Sync Mode) | 50/60±4Hz (Sync Mode) | 50/60±4Hz (Sync Mode) | 50/60±4Hz (Sync Mode) |
| Overload Capability | 105-125%: ≥60s | 105-125%: ≥60s | 105-125%: ≥60s | 105-125%: ≥60s | 105-125%: ≥60s |
| Transfer Time | 0ms | 0ms | 0ms | 0ms | 0ms |
| Efficiency (Line Mode) | 86% (HV) | 88% (HV) | 89% (HV) | 92% (HV) | 93% (HV) |
| Efficiency (Battery Mode) | 85% | 86% | 87% | 87% | 87% |
| Nominal Battery Voltage | 24V | 48V | 72V | 144/192V | 192/240V |
| Battery Capacity & Quantity | 12V/7AH x 2pcs | 12V/7AH x 4pcs | 12V/7AH x 6pcs | 12V/7AH x 12/16pcs | 12V/7AH x 16/20pcs |
| Backup Time (Standard) | Half Load≥8min, Full Load≥3min | Half Load≥6min, Full Load≥3min | Half Load≥6min, Full Load≥3min | Depends on Battery Config | Depends on Battery Config |
| Charging Time | 90% in 5 hours | 90% in 5 hours | 90% in 5 hours | 90% in 5 hours | 90% in 5 hours |
| Noise | <50dB | <50dB | <50dB | <55dB | <55dB |
| Communication | RS232 | RS232 | RS232 | RS232 | RS232 |

| Application | Description |
|---|---|
| Data Center | Provides uninterrupted power protection for data center servers, storage devices, and network equipment. |
| Server Room | Protects critical IT equipment such as enterprise servers, switches, and routers. |
| Telecommunication Base Station | Provides stable and reliable power guarantee for telecommunication base station equipment. |
| Financial System | Protects computer systems and trading equipment of banks, securities, insurance and other financial institutions. |
| Medical Equipment | Provides uninterrupted power for medical instruments, monitoring equipment, and information systems. |
| Educational Institution | Protects electronic equipment in school computer rooms, laboratories, and multimedia classrooms. |
| Government Office | Provides power protection for information systems and office equipment of government departments. |
| Industrial Control | Protects industrial automation equipment, PLC control systems, and monitoring systems. |
| Retail POS System | Protects supermarket and shopping mall cash register systems and data terminals. |
| Home Office | Provides power protection for home servers, NAS, and network equipment. |
| Item | Detail |
|---|---|
| Quality System | ISO9001 Quality Management System Certification |
| Product Certification | CE Certified (Compliant with relevant standards) |
| Testing Process | 100% full inspection + 48-hour full-load aging test |
| Warranty | 12 months standard warranty, extendable to 36 months |
| After-sales Service | Lifetime technical support, 7×24 rapid response |
|
Advantage
|
Description
|
|---|---|
|
Source Factory
|
Nearly 20 years of power equipment manufacturing experience, own production lines, cost-controlled, guaranteed delivery.
|
|
Quality Assurance
|
100% inspection + 48-hour aging test, ISO9001 certified, product yield rate over 99.7%.
|
|
Flexible Customization
|
Supports non-standard customization for capacity, voltage, communication interface, etc., meeting special requirements.
|
|
Global Service
|
7×24 technical support, 12-month warranty (extendable), lifetime maintenance.
|
|
Professional Team
|
Experienced R&D engineers and foreign trade team, providing selection guidance and technical consultation.
|
|
Technical Accumulation
|
Nearly 20 years of UPS manufacturing technical accumulation, mature and reliable products, compliant with international standards.
|
FAQ
Q1: What is the difference between on-line UPS and off-line UPS?
A: On-line UPS adopts double conversion topology. The mains input is first rectified and then inverted to output, always providing clean and stable sine wave power to the load with zero transfer time. Off-line UPS directly outputs mains when normal, and only switches to battery inverter output when mains is abnormal, with a transfer time of usually 4-10ms. On-line UPS provides the highest level of power protection.
Q2: What is the output power factor of this UPS?
A: The output power factor is 1.0, meaning a 1000VA UPS can support 1000W of equipment, providing stronger load capacity than traditional PF=0.8 UPS.
Q3: How to choose between standard model (with battery) and long backup time model (without battery)?
A: Standard models (e.g., 1K) have built-in batteries, suitable for short backup time (about 3 minutes at full load). Long backup time models (e.g., 1KS) do not have built-in batteries and require external battery packs, which can be configured with large capacity batteries for long backup time.
Q4: What communication interfaces does this UPS support?
A: Standard RS232 communication interface, optional SNMP card (network management), USB card, dry contact card (AS400 card), etc., for remote monitoring and management.
Q5: What is the noise level of this UPS?
A: 1-3kVA models noise <50dB, 6-10kVA models noise <55dB, quiet operation suitable for office and computer room environments.
Q6: Can this UPS be started without mains power?
A: Yes. This UPS supports battery cold start function, which can directly start the UPS from battery to power the load without mains input.
Q7: What distinguishes your Single Phase On-line Tower UPS compared to other UPS systems?
Our UPS uses a double conversion on-line topology with DSP digital control, providing zero transfer time and a pure sine wave output with an output power factor of 1. This setup ensures stable, clean power ideal for demanding environments, making it a superior choice among industrial UPS suppliers.
Q8: Can you customize the UPS to fit specific power requirements or communication needs?
Yes, we offer optional communication interfaces including SNMP, USB, and dry contact cards to support remote monitoring. Our Single Phase On-line Tower UPS can be tailored to match your system’s power range from 1 to 10kVA, ensuring compatibility with your critical load demands and integration into your data center ups system.
Q9: What should I consider regarding installation and space requirements for this UPS?
Our UPS comes in a compact tower design optimized for effective heat dissipation and space efficiency. It supports single-phase input/output and requires standard electrical installation procedures. Its adaptability suits server rooms, telecom sites, and industrial floors where space and reliable power are priorities.
Q10: How do you ensure product quality and what after-supply support is provided?
We manufacture under strict ISO9001 standards with 100% quality inspection and a 48-hour full-load aging test, ensuring high reliability. Our UPS units come with a 12-month warranty, extendable to 36 months, and we provide global technical support to maintain your industrial UPS system’s consistent operation.
We look forward to becoming your reliable power solution partner!